Operation - Operating instruments
6 - 34
830 / 07.2012
Original operating instructions
Note
Particulate filter regeneration should be authorized at the next
opportunity.
The particulate filter can only be regenerated manually if the load status
of the diesel particulate filter is adequate for the regeneration process.
If the load status is adequate, the following pilot lamp appears in
SENCON:
To start the manual regeneration process, the engine must be run at an
idle speed of 800 rpm.
No operating functions can be executed during manual regeneration.
Note
Observe the notes in the engine manufacturer's operating instructions.
DANGER
High exhaust temperatures can occur!
If there are exhaust temperatures above 625°C the following pilot lamp
lights up in SENCON:
Non-observance of notes in the engine manufacturer's operating
instructions can lead to damage to property and personal injuries.