Name Use Data type Definition Values Safety implica‐
t
ion
SetMonitoringCaseNoTable2 Safety function USINT Monitoring case num‐
ber (Monitoring case
table 2)
Activates the monitor‐
ing case with the cor‐
responding number in
monitoring case table
02.
0 = invalid Safety-relevant
parameter
1 … 254 = num‐
ber of t
he moni‐
toring case
SetMonitoringCaseNoTable3 Safety function USINT Monitoring case num‐
ber (Monit
oring case
table 3)
Activates the monitor‐
ing case with the
respective number in
monitoring case table
03.
0 = invalid Safety-relevant
parameter
1 … 254 = num‐
ber of the moni‐
toring case
SetMonitoringCaseNoTable4 Safety function USINT Monitoring case num‐
ber (Monit
oring case
table 4)
Activates the monitor‐
ing case with the cor‐
responding number in
monitoring case table
04.
0 = invalid Safety-relevant
parameter
1 … 254 = num‐
ber of t
he moni‐
toring case
Speed1 Safety function INT Speed at dynamic con‐
t
rol input 1
-32000 ...
+32000 = speed
in mm/s
Safety-relevant
parameter
Speed1Valid Safety function BOOL Speed1 valid 0 = Invalid speed Safety-relevant
parameter
1 = speed valid
Speed2 Safety function INT Speed at dynamic con‐
t
rol input 2
-32000 ...
+32000 = speed
in mm/s
Safety-relevant
parameter
Speed2Valid Safety function BOOL Speed2 valid 0 = Invalid speed Safety-relevant
parameter
1 = speed valid
StopAlarmDetection Additional func‐
t
ion
BOOL Stop Event history 0 = event history
active, field inter‐
ruptions are
recorded
Parameter with‐
out safety impli‐
cation
1 = event history
not active, field
interruptions are
not recorded,
existing record‐
ings are retained
TriggerDeviceRebootWithNet‐
work
Additional func‐
tion
BOOL Restart device com‐
pletely
Restarts the device and
the network stack. The
internal switch function
is interrupted.
0 = no restart Parameter with
implication for
the safety func‐
tion
0-1-0 = device
r
estart
(duration of sta‐
tus 1 ≥ 120 ms)
1 = ignored
TECHNICAL DATA 13
8025424/1ELL/2022-01-21 | SICK O P E R A T I N G I N S T R U C T I O N S | microScan3 Pro I/O