S120 Combi Power Modules
4.8 Electrical connection
SINAMICS S120 Combi
104 Manual, 11/2017, 6SL3097-4AV00-0BP7
WARNING
Electric shock when using end sleeves without insulation support
If you use end sleeves without insulation support (according to DIN 46228-A), there is a
danger of touching live parts with your fingers.
Establish touch protection by using shrink tubing
Figure 4-24 Stripped lengths for power cables
Table 4- 20 Stripped lengths with tolerances
Cable cross-section in mm
2
A in mm and (inches)
4 x 1.5
55
+3
(2.17
+0.12
)
4 x 2.5
55
+3
(2.17
+0.12
)
4 x 4
55
+3
(2.17
+0.12
)
4 x 6 55
+2
(2.17
+0.08
)
4 x 10
55
+2
(2.17
+0.08
)