DC link components   
7.3 Braking resistors 
  SINAMICS S120 Combi 
176  Manual, 11/2017, 6SL3097-4AV00-0BP7 
 
 
A braking resistor is used to dissipate the excess DC link energy in generator operation. One 
braking resistor is connected to one Braking Module. 
Resistors without thermostatic switch are available with various power ratings. 
The braking resistors can be installed standing on the floor of the control cabinet or 
suspended. You must ensure that the braking resistors do not obstruct the flow of cooling air 
to the drive line-up. 
Positioning the braking resistor outside the control cabinet or switchgear room enables the 
resulting thermal losses to be routed away. This reduces the level of air conditioning 
required. 
A shielded connection cable (3 m, 3 x 1.5 mm
2
) is supplied with braking resistor 6SN1113-
1AA00-0DA0. 
Other braking resistors are supplied without connecting cable. The maximum conductor 
cross-sections are listed in the technical data. 
The maximum cable length for all braking resistors is 10 m.