Service and maintenance
13.2 Replacing the fan
SINAMICS S120 Combi
306 Manual, 11/2017, 6SL3097-4AV00-0BP7
13.2
Replacing the fan
13.2.1
Safety instructions when replacing a fan
WARNING
Electric shock due to applied voltage or residual charge
Switch off the power supply (400 VAC) before replacing the fan.
A hazardous voltage is still present for up to 5 minutes after the power supply has been
switched off.
Contact with live parts can result in death or serious injury.
• Remove the device cover or the fan cover only after 5 minutes have elapsed.
• Check for zero voltage before removing the component.
WARNING
Electric shock when live parts are touched during fan replacement
Contact with live parts while the fan is being replaced can result in death or serious injury.
• When removing the fan, you must observe the ESD regulations.
• Assign qualified personnel to install spare parts.
13.2.2
Replacing the Internal fan on the S120 Combi Power Module
When required, the internal S120 Combi fan can be replaced. It can be ordered as a spare
part (Article number: 6SL3161-0JP00-0AA0).
Removing the internal fan
1. Remove the S120 Combi front plate (see Section "Electrical connection of Motor Modules
and DC-link components (Page 181)")

Table of Contents

Other manuals for Siemens SINAMICS S120 Combi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S120 Combi and is the answer not in the manual?

Siemens SINAMICS S120 Combi Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S120 Combi
CategoryControl Unit
LanguageEnglish

Related product manuals