S120 Combi Power Modules
4.9 Technical data
SINAMICS S120 Combi
108 Manual, 11/2017, 6SL3097-4AV00-0BP7
4.9
Technical data
Table 4- 21 Technical data of the S120 Combi 3 axes Power Modules
3 axes Power Modules
6SL3111-
3VE21-6FA1
3VE21-6EA1
3VE22-0HA1
16 kW / 18 A /
5 A / 5 A
16 kW / 24 A /
9 A / 9 A
20 kW / 30 A /
9 A / 9 A
Infeed
Infeed
Rated power (S1)
1)
Infeed power for S6 duty P
S6
(40 %)
1)
Peak infeed power
1)
kW (P
n
)
kW (P
s6
)
kW (P
max
)
16
21
35
16
21
35
20
26.5
40
Regenerative feedback
Rated power (S1)
Peak regenerative power
kW (P
n
)
kW (P
max
)
16
35
16
35
20
40
Supply voltages
Line voltage
Line frequency
Electronics power supply
V
AC
Hz
V
DC
3 AC 380 10 % … 3 AC 480 + 10 %
45 … 66
24 (20.4 … 28.8)
Rated input current
at 400 V AC
at 380 V AC / 480 V AC
at 400 V; for S6 duty I
S6
(40 %)
at 400 V AC peak current
A
AC
A
AC
A
AC
A
AC
28
29 / 25
35.5
56
28
29 / 25
35.5
56
34
35 / 30
44
63.5
Spindle
Output current
Rated current (I
n
)
Base-load current (I
H
)
Intermittent duty current for S6 duty I
S6
(40%)
Peak current (I
max
)
A
ACrms
A
ACrms
A
ACrms
A
ACrms
18
15.3
24
36
24
20.4
32
48
30
25.5
40
56
Rated power
at 540 V DC link voltage
at 600 V DC link voltage
kW
kW
8.7
9.7
11.7
13
14.4
16
Pulse frequency spindle
kHz
4
4
4
Output voltage
V
ACrms
0 … 0.7 x DC link voltage
Feedrate 1
Output current
Rated current (I
n
)
Base-load current (I
H
)
Intermittent duty current for S6 duty I
S6
(40%)
Peak current (I
max
)
A
ACrms
A
ACrms
A
ACrms
A
ACrms
5
4.3
6.5
10
9
7.7
12
18
9
7.7
12
18
Rated power
at 540 V DC link voltage
at 600 V DC link voltage
kW
kW
2.4
2.7
4.3
4.8
4.3
4.8
Pulse frequency feedrate 1
kHz
4
4
4
Output voltage
V
ACrms
0 … 0.7 x DC link voltage
Feedrate 2

Table of Contents