Encoder system connection   
10.4 Sensor Module External SME25 
  SINAMICS S120 Combi 
258  Manual, 11/2017, 6SL3097-4AV00-0BP7 
 
Table 10- 19  Encoder system interface SME25 
 
 
 
4  M  Ground for encoder power supply 
8  Clock  Clock, EnDat interface,  
9  Clock*  Inverted clock, EnDat interface,  
Ground for encoder power supply  
Inverse incremental signal B 
14  Data  Data, EnDat interface,  
Inverse incremental signal A 
17  Data*  Inverse data, EnDat interface,  
17-pin, article number: 6FX2003-0SA17 
Blanking plate for encoder system interface: Pöppelmann GmbH & Co. KG, Lohne,  
Article number: GPN 300 F211 
 
Electric shock in the event of voltage flashovers at the temperature sensor 
Voltage flashovers in the signal electronics can occur in motors without safe electrical 
separation of the temperature sensors. 
•  Use temperature sensors that comply with the specifications relating to protective 
separation. 
•  If safe electrical separation cannot be guaranteed (for linear motors or third-party 
motors, for example), use a Sensor Module External (SME120 or SME125) or Terminal 
Module TM120.