Cabinet design and EMC
12.8 Note on control cabinet cooling
SINAMICS S120 Combi
300 Manual, 11/2017, 6SL3097-4AV00-0BP7
12.8.4
Power loss of components in rated operation
12.8.4.1
General information
The tables below provide an overview of the power loss of all components during rated
operation. The characteristic values apply for the following conditions:
Line supply voltage 400 V
Pulse frequency of the Motor Modules 4 kHz (clock frequency of the spindle 4 kHz or 8
kHz)
Operating components at their rated power
The total losses of the relevant components (S120 Combi, Motor Module) are calculated
from the power loss and the corresponding losses from the electronics.
12.8.4.2
Power losses for SINUMERIK control systems, DC link components and
supplementary system components
Table 12- 17 Overview of power losses at rated operation for SINUMERIK control systems, DC link
components and supplementary system components
Unit
Power loss
SINUMERIK 828D
W
28
SINUMERIK NCU 710.3 PN W 21
SMC20/30
W
< 10
SME20/25
W
< 4
TM54F
W
4.5
Braking Module
W
20
Control Supply Module
Line
DC link
W
W
70
65

Table of Contents

Other manuals for Siemens SINAMICS S120 Combi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S120 Combi and is the answer not in the manual?

Siemens SINAMICS S120 Combi Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S120 Combi
CategoryControl Unit
LanguageEnglish

Related product manuals