Motor Modules Booksize Compact as expansion axes
6.8 Technical data
SINAMICS S120 Combi
146 Manual, 11/2017, 6SL3097-4AV00-0BP7
Table 6- 10 Technical data Double Motor Modules Booksize Compact (2 x 1.7 A to 2 x 5 A)
Double Motor Modules Booksize Compact
Rated current (I
n
)
Base load current (I
H
)
Intermittent duty current for S6 duty I
S6
(40 %)
max
A
ACrms
A
A
ACrms
ACrms
2 x 1.5
2 x 2
2 x 2.6
2 x 3.5
2 x 4.3
2 x 6
0 … 0.717 x DC link voltage
d max
DC
(up to 2000 m above sea level)
V
DC
510 … 720
1)
V
DC
820 ± 2 %
DC
Electronics current drawn at 24 V DC
Current carrying capacity
DC link busbar
Reinforced DC link busbars
A
A
100
150
100
150
100
150
2)
Based on I
n
(600 V, 8 kHz)
Based on I
H
kW
kW
2 x 0.9
2 x 0.8
2 x 1.6
2 x 1.4
2 x 2.7
2 x 2.3
(including electronics losses) at 8 kHz
(see Power loss tables (Page 300))
W 114 134 194
Without derating
kHz
8
8
8
Without derating
°C
40
Internal air cooling using an integrated fan
3
Default setting for 400 V line supplies, undervoltage trip threshold can be reduced by up to 80 V and is adjusted to the
parameterized line voltage
2)
Rated power of a typical standard induction motor at 400 V 3 AC.