EasyManuals Logo

Siemens SINAMICS S120 Combi User Manual

Siemens SINAMICS S120 Combi
330 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #80 background imageLoading...
Page #80 background image
S120 Combi Power Modules
4.3 Interface description
SINAMICS S120 Combi
80 Manual, 11/2017, 6SL3097-4AV00-0BP7
Table 4- 15 Specification of TTL encoder systems that can be connected
Parameter
Designation
Threshold
Min.
Max.
Unit
Signal level, high
1)
U
Hdiff
2
5
V
Signal level, low
1)
U
Ldiff
-5
-2
V
Signal frequency
f
S
-
300
kHz
Edge clearance
t
min
100
-
ns
"Zero pulse inactive time"
(before and after A=B=high)
t
Lo
640 (t
ALo-BHi
- t
Hi
)/2
2)
ns
"Zero pulse active time"
(while A=B=high and beyond)
3)
t
Hi
640 t
ALo-BHi
- 2*t
Lo
2)
ns
1)
Other signal levels according to the RS422 standard.
2)
t
ALo-BHi
is not a specified value, but is the time between the falling edge of track A and the next but one rising edge of
track B.
3)
Further information on setting the "Zero pulse active time" can be found in the following:
References: SINAMICS S120 Drive Functions Function Manual, Section "Tolerant encoder monitoring"

Table of Contents

Other manuals for Siemens SINAMICS S120 Combi

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS S120 Combi and is the answer not in the manual?

Siemens SINAMICS S120 Combi Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS S120 Combi
CategoryControl Unit
LanguageEnglish

Related product manuals