S120 Combi Power Modules   
4.3 Interface description 
  SINAMICS S120 Combi 
80  Manual, 11/2017, 6SL3097-4AV00-0BP7 
Table 4- 15  Specification of TTL encoder systems that can be connected  
1)
Hdiff
1)
Ldiff
"Zero pulse inactive time" 
(before and after A=B=high) 
t
Lo
    640  (t
ALo-BHi
 - t
Hi
)/2
2)
  ns 
"Zero pulse active time" 
(while A=B=high and beyond) 
3)
t
Hi
    640  t
ALo-BHi
 - 2*t
Lo
2)
  ns 
  Other signal levels according to the RS422 standard. 
  t
ALo-BHi
 is not a specified value, but is the time between the falling edge of track A and the next but one rising edge of 
track B. 
  Further information on setting the "Zero pulse active time" can be found in the following:  
References: SINAMICS S120 Drive Functions Function Manual, Section "Tolerant encoder monitoring"