Cabinet design and EMC Booksize
12.4 Arrangement of components and equipment
Booksize Power Units
Manual, (GH2), 07/2016, 6SL3097-4AC00-0BP8
679
Variant 2: Module width 50-100 mm, connected to the drive line-up from the right, reinforced DC-link
busbar
DC-link adapter 6SL3162-2BM10-0AA0 (2 hole)
Reinforced DC-link busbar (8 mm)
Connecting the DC-link adapter to the DC-link busbar using 2 M4x20 screws
Figure 12-7 Variant 2 (representation from below)
Variant 3: Module width 50-100 mm, connected to the drive line-up from the left, standard DC-link
busbar
DC-link adapter 6SL3162-2BM01-0AA0 (4 hole)
Standard DC-link busbar (4 mm)
Connecting the DC-link adapter to the module using 2 M4x16 screws
Connecting the DC-link busbar to the module using 2 M4x20 screws
DC-link bridge
Figure 12-8 Variant 3 (representation from below)