F01123 Power unit does not support digital inputs/outputs
Message class: Error in the parameterization / conguration / commissioning pr
ocedure (18)
Message value: -
Component: Power Unit
Response: OFF1
Acknowledgment: IMMEDIATELY
Cause: The power unit does not support the activated "Digital inputs/outputs" function.
Remedy: Deactivate function.
F01150 CU: Number of instances of a drive object type exceeded
Message class: Error in the parameterization / congur
ation / commis
sioning pr
ocedure (18)
Message value: Drive object type: %1, number permitted: %2, actual number: %3
Component: None
Response: NONE
Acknowledgment: IMMEDIATELY
Cause: The maximum permissible number of instances of a drive object type was exceeded.
No
te r
egarding the message value:
The individual information is coded as follows in the message value (r0949/r2124):
ddccbbaa hex:
aa = drive object type:
- Drive object type (p0107), for which the maximum permissible number of instances was exceeded.
bb = number permitted:
- Maximum permissible number of instances for this drive object type.
cc = actual number:
- Actual number of instances for this drive object type.
dd = no signicance
Remedy: - Switch o the unit.
- Suitabl
y restrict the number of instances of a drive object type by reducing the number of inserted components.
- Re-commission the unit.
F01151 CU: Number of drive objects of a category exceeded
Message class: Error in the parameterization / conguration / commissioning pr
ocedure (18)
Message value: Drive object category: %1, number permitted: %2, actual number: %3
Component: None
Response: NONE
Acknowledgment: IMMEDIATELY
Cause: The maximum permissible number of drive objects of a category was exceeded.
No
te r
egarding the message value:
The individual information is coded as follows in the message value (r0949/r2124):
ddccbbaa hex:
aa = drive object category:
- Drive object category, for which the maximum permissible number of drive objects was exceeded.
bb = number permitted:
- Maximum permissible number for this drive object category.
cc = actual number:
- Actual number for this drive object category.
dd = no signicance
Remedy: - Switch o the unit.
- Suitabl
y restrict the number of drive objects of the specied category by reducing the number of inserted components.
- Re-commission the unit.
System messages
12.3Faults and alarms
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 453