Acknowledgment: NONE
Explanation of the
mes
sage v
alue:
For %1
Component in target topology
Explanation of the
mes
sage v
alue:
For %2, %3
Value Cause Remedy
0 Component unknown
1 Control Unit
2 Motor Module
3 Line Module
4 Sensor Module
5 Voltage Sensing Module
6 Terminal Module
7 DRIVE-CLiQ Hub Module
8 Controller Extension
9 Filter module
10 Hydraulic Module
49 DRIVE-CLiQ component
50 Option slot
60 Encoder
70 DRIVE-CLiQ motor
71 Hydraulic cylinder
72 Hydraulic valve
80 Motor
Explanation of the
mes
sag
e v
alue:
For %4
Value Cause Remedy
1 Dierent component type
2 Dierent article number
3 Dierent manufacturer
4 Incor
rect subcomponent connected
5 NX10 or NX15 used instead of CX32.
6 CX32 used instead of NX10 or NX15.
7 Dierent number of connections
Cause: The topology comparison has detected dier
ences in t
he actual and t
arget topologies in the electronic nameplate
component.
Alarm value (r2124, interpret hexadecimal):
ddccbbaa hex:
aa = component number (%1),
bb = component class of the target topology (%2),
cc = component class of the actual topology (%3),
dd = dierence (%4)
Note:
The component class is described in F01375.
The drive system is no longer booted. In this state, the drive control (closed-loop) cannot be enabled.
System messages
12.3Faults and alarms
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 465