Message value: Module: %1, line: %2
Variant: S200 PN
Component: Control Unit (CU)
Response: OFF2
Acknowledgment: IMMEDIATELY
Cause: An internal error has occurred in the Safety Integrated software.
No
te:
This mes
sage results in an STO (Safe Torque O󹪜) that cannot be acknowledged.
Message value (r60049, interpret hexadecimal): Only for internal Siemens fault diagnostics.
Remedy: - Carry out a POWER ON (switch-o󹪜/switch-on) f
or all components.
- Re-commission the "Safety Integrated" function and carry out a POWER ON.
- Upgrade 󹪝rmware to later version.
- Contact Technical Support.
- Replace hardware component.
F01650 SI: Acceptance test required
Message class: Safety monitoring channel has identi󹪝ed an error (10)
Mes
sage value: %1
Variant: S200 PN
Component: Control Unit (CU)
Response: OFF2
Acknowledgment: IMMEDIATELY
Cause: The drive-integrated "Safety Integrated" function requires an acceptance test.
Mes
sage v
alue (r0949, interpret decimal):
2003: Acceptance test is required as a safety parameter has been changed.
Remedy: For message value = 2003:
- Carry out an accep
tance test and generate an acceptance report.
The procedure when carrying out an acceptance test as well as an example of the acceptance report are provided in the
product operating instructions.
F01661 SI: Simulation of the safety inputs active
Message class: General drive fault (19)
Message value: Fault cause: %1 bin
Variant: S200 PN
Component: Control Unit (CU)
Response: OFF2
Acknowledgment: IMMEDIATELY
Cause: The simulation of the digital inputs is active (p0795).
It is no
t permissible t
hat safety inputs are simulated.
Fault value (r0949, interpret binary):
The displayed bits indicate which digital inputs must not be simulated.
Remedy: - Deactivate the simulation of the digital inputs for the safety inputs (p0795).
- Ackno
wledge fault.
C01668 SI: Checksum error safety monitoring functions
Message class: Safety monitoring channel has identi󹪝ed an er
r
or (10)
Mes
sage value: %1
Variant: S200 PN
Component: Control Unit (CU)
Response: OFF2
System messages
12.3Faults and alarms
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
480 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS SIMOTICS S200 PROFINET and is the answer not in the manual?

Siemens SINAMICS SIMOTICS S200 PROFINET Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS SIMOTICS S200 PROFINET
CategoryServo Drives
LanguageEnglish

Related product manuals