F07475 EPOS: Target position < start of traversing range
Message class: Error in the parameterization / con󹪝guration / commissioning pr
ocedure (18)
Message value: -
Component: None
Response: OFF1
Acknowledgment: IMMEDIATELY
Cause: The target position for relative traversing lies outside the traversing range.
Remedy: Correct the target position.
F07476 EPOS: Target position > end of the traversing range
Message class: Error in the parameterization / con󹪝gur
ation / commis
sioning pr
ocedure (18)
Message value: -
Component: None
Response: OFF1
Acknowledgment: IMMEDIATELY
Cause: The target position for relative traversing lies outside the traversing range.
Remedy: Correct the target position.
A07477 EPOS: Target position < negative software limit switch
Message class: Error in the parameterization / con󹪝guration / commissioning pr
ocedure (18)
Message value: -
Component: None
Response: NONE
Acknowledgment: NONE
Cause: In the actual traversing operation, the target position is less than the negative software limit switch.
Remedy: - Correct the target position.
- Chang
e the neg
ative software limit switch (c2578, p2580).
See also: c2578 (EPOS negative software limit switch), p2580 (EPOS negative software limit switch), c2582 (EPOS software
limit switch activation)
A07478 EPOS: Target position > positive software limit switch
Message class: Error in the parameterization / con󹪝guration / commissioning pr
ocedure (18)
Message value: -
Component: None
Response: NONE
Acknowledgment: NONE
Cause: In the actual traversing operation, the target position is greater than the positive software limit switch.
Remedy: - Correct the target position.
- Chang
e the positiv
e software limit switch (c2579, p2581).
See also: c2579 (EPOS positive software limit switch), p2581 (EPOS positive software limit switch), c2582 (EPOS software
limit switch activation)
A07479 EPOS: Negative software limit switch reached
Message class: Application/technological function faulted (17)
Message value: -
Component: None
Response: NONE
Acknowledgment: NONE
Cause: The axis is at the position of the negative software limit switch. An active traversing block was interrupted.