Message value: -
Component: Control Unit (CU)
Response: NONE
Acknowledgment: NONE
Cause: - For the converter, the options that require a license are being used but the licenses are not sucient.
- An er
ror occur
red when checking the existing licenses.
Alarm value (r2124, interpret decimal):
0: The existing license is not sucient.
1: An adequate license was not able to be determined as the memory card with the required licensing data was withdrawn
in operation or the memory card has developed a defect.
2: An adequate license was not able to be determined as there is no licensing data available on the memory card.
3: An adequate license was not able to be determined as there is no licensing data available on the memory card.
4, 5, 6, 7: An adequate license was not able to be determined as the licensing data were manipulated and are therefore
invalid.
8,9: An internal error occurred when checking the license.
Remedy: For alarm value = 0:
Additional licenses are r
equired and must be activated.
For alarm value = 1:
Reinsert or replace the memory card that matches the system.
For alarm value = 2:
Transfer the license le to the converter.
For alarm value = 3:
Compare the license le name (after "LK_" to ".ZIP") with the serial number of the memory card.
Transfer the appropriate license le to the converter.
For alarm value = 4, 5, 6, 7, 8, 9:
- Carry out a POWER ON.
- Upgrade rmware to later version.
- Contact Technical Support.
Note:
An overview of the converter functions requiring a license can be displayed using a commissioning tool in the online mode.
Depending on the commissioning tool, you can also obtain the necessary licensing (serial number, license le, Trial License
Mode).
A13030 Trial License activated
Message class: Error in the parameterization / conguration / commissioning pr
ocedure (18)
Message value: -
Component: Control Unit (CU)
Response: NONE
Acknowledgment: NONE
Cause: The "Trial License" function was activated. One of the available periods is expiring.
Remedy: Not necessary.
The alarm is aut
omatically wit
hdrawn after the periods have expired.
A13031 Trial License period expired
Message class: Error in the parameterization / congur
ation / commissioning pr
ocedure (18)
Message value: -
Component: Control Unit (CU)
Response: NONE
Acknowledgment: NONE
Cause: One of the available periods of the "Trial License" function has expired.
System messages
12.3Faults and alarms
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 539