EasyManuals Logo

Siemens SINAMICS SIMOTICS S200 PROFINET User Manual

Siemens SINAMICS SIMOTICS S200 PROFINET
908 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #586 background imageLoading...
Page #586 background image
Response: OFF1
Acknowledgment: POWER ON
Cause: An internal software error has occurred.
F
ault value (r0949, interpret decimal):
Information about the fault source.
Only for internal Siemens troubleshooting.
Remedy: - If necessary, upgrade the 󹪝rmwar
e in the Sensor Module to a later version.
- Contact Technical Support.
A32999 Encoder 2: Unknown alarm
Message class: Position/speed actual value incorrect or not available (11)
Message value: New message: %1
Component: Sensor Module Encoder 2
Response: NONE
Acknowledgment: NONE
Cause: An alarm has occurred on the Sensor Module for encoder 2, which cannot be interpreted by the converter 󹪝rm
w
ar
e.
This can occur if the 󹪝rmware on this component is more recent than the converter 󹪝rmware.
Alarm value (r2124, interpret decimal):
Alarm number.
Note:
If required, the signi󹪝cance of this new alarm can be read about in a more recent description of the converter.
Remedy: - Replace the 󹪝rmwar
e on the Sensor Module by an older 󹪝rmware version.
- Upgrade the converter 󹪝rmware.
F33899 Encoder 3: Unknown fault
Message class: Position/speed actual value incorrect or not available (11)
Message value: New message: %1
Component: Sensor Module Encoder 3
Response: OFF1
Acknowledgment: IMMEDIATELY
Cause: A fault occurred on the Sensor Module for encoder 3, which cannot be interpreted by the converter 󹪝rm
war
e.
This can occur if the 󹪝rmware on this component is more recent than the converter 󹪝rmware.
Fault value (r0949, interpret decimal):
Fault number.
Note:
If required, the signi󹪝cance of this new fault can be read about in a more recent description of the converter.
Remedy: - Replace the 󹪝rmwar
e on the Sensor Module by an older 󹪝rmware version.
- Upgrade the converter 󹪝rmware.
A33999 Encoder 3: Unknown alarm
Message class: Position/speed actual value incorrect or not available (11)
Message value: New message: %1
Component: Sensor Module Encoder 3
Response: NONE
Acknowledgment: NONE
System messages
12.3Faults and alarms
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
584 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS SIMOTICS S200 PROFINET and is the answer not in the manual?

Siemens SINAMICS SIMOTICS S200 PROFINET Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS SIMOTICS S200 PROFINET
CategoryServo Drives
LanguageEnglish

Related product manuals