The parameter number has the following syntax: pxxxx[0...n], rxxxx[0...n], cxxxx[0...n],
pxxxx.0...15 or rxxxx.0...15, cxxxx.0...15, pxxxx[0...n].0...15 or rxxxx[0...n].0...15,
cxxxx[0...n].0...15.
Ex
amples of representation in the parameter list:
p... Adjustable parameters (read and write)
r... Display parameters (read-only)
c... Display parameters (read-only)
p0972 Adjustable parameter 972
p0489[0...2] Adjustable parameter 489, index0 to 2
r0945 Display parameter 945
r0196[0...255].0...15 Display parameter with index 0 to 255 and bit array from bit 0 to bit
15
r5613.0...1 Display parameter 5613 with bit array from bit 0 to bit 1
c8997[0...2] Display parameter 8997, index 0 to 2
Other examples of the notation in the documentation:
p9563[1] Adjustable parameter 9563, index 1
r0196[1].5 Display parameter 196, index 1, bit 5
r0964[2] Display parameter 964, index 2
p5611.1 Adjustable parameter 5611, bit 1
Parameter name
Sho
ws the parameter name in the long form.
Variant
Speci󹪝es the product variant for which the parameter is valid. This information is not
applicable if a parameter is the same for all product variants used in the parameter list.
For parameters that displayed only once
S200PN: The parameter applies to the S200PN converter only.
S200BasicPN: The parameter applies to the S200BasicPN converter only.
For parameters that dispalyed twice
S200 Basic PN (EPOS load side, rotating), S200 PN (EPOS load side, rotating): The
parameter is used in the "rotary" axis type application only and applies to both the S200 PN
converter and the S200Basic PN converter.
blank: The parameter is used in the "linear" axis type application only and applies to both
the S200PN converter and the S200Basic PN converter.
Data type
Each parameter is assigned one of the following data types:
Integer8 I8 8-bit integer
Integer16 I16 16-bit integer
Integer32 I32 32-bit integer
Unsigned8 U8 8-bit without sign
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
692 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SINAMICS SIMOTICS S200 PROFINET and is the answer not in the manual?

Siemens SINAMICS SIMOTICS S200 PROFINET Specifications

General IconGeneral
BrandSiemens
ModelSINAMICS SIMOTICS S200 PROFINET
CategoryServo Drives
LanguageEnglish

Related product manuals