Description: Selects the input terminal for connecting an equivalent zero mark (external encoder zero mark).
Value: 0: No equivalent zero mark (evaluation of the encoder zero mark)
210: DI 0 (X130.1)
211: DI 1 (X130.2)
Dependency: See also: p0490
CAUTION
In order to prevent incorrect measurement values, these parameters may not be written during an active measurement.
Note
Ref
er t
o t
he encoder interface for PROFIdrive.
p0550[0] Brake version
Data type: Integer16 V
isible in: Extended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Can be changed in the operating
stat
e:
Commissioning
Parameter group: Motor holding brake, Quick commissioning
Unit: -
Min:
0
Max:
2
Factory setting:
0
Description: Sets the brake version.
Value: 0: No data
1: Holding brake
2: High performance holding brake
NOTICE
After entering a corresponding code number (p0551), this parameter is automatically pre-assigned and write
pr
ot
ected. The information in p0551 should be observed when removing write protection.
Note
For p0550 = 1:
The default value f
or opening time/closing time applies.
For p0550 = 2:
A shorter opening time/closing time is realized if the power unit supports the function.
p0551[0] Brake code number
Data type: Unsigned32 Visible in: Ext
ended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Can be changed in the operating
stat
e:
Commissioning
Parameter group: Motor holding brake, Quick commissioning
Unit: -
Min:
0
Max:
4294967295
Factory setting:
1
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 719