p0952 Fault cases counter
Data type: Unsigned16 Visible in: Ext
ended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Can be changed in the operating
stat
e:
Operation
Parameter group: Faults / alarms
Unit: -
Min:
0
Max:
65535
Factory setting:
0
Description: Number of fault situations that have occurred since the last reset.
Dependency: The fault bu󹪜er is dele
t
ed (clear
ed) by setting p0952 to 0.
In order that faults with "POWER ON" acknowledgment can also be cleared from the fault bu󹪜er, POWER ON must 󹪝rst
be carried out.
See also: r0945, r0947, r0948, r0949, r2109, r2130, r2133, r2136
r0964[0...6] Device identi󹪝cation
Data type: Unsigned16 Visible in:
Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: System identi󹪝cation
Unit: -
Description: Displays the device identi󹪝cation.
Index: [0] = Company (Siemens = 42)
[1] = Device type
[2] = Firm
ware version
[3] = Firmware date (year)
[4] = Firmware date (day/month)
[5] = Reserved
[6] = Firmware patch/hot 󹪝x
Note
Example:
r0964[0] = 42 --> SIEMENS
r0964[1] = de
vice type, see below
r0964[2] = 602 --> 󹪝rst part 󹪝rmware version V06.02 (second part, refer to index 6)
r0964[3] = 2023 --> year 2023
r0964[4] = 1706 --> June 17
r0964[5] = 1 --> 1 (󹪝xed value)
r0964[6] = 0 --> second part 󹪝rmware version (complete version: V06.02.00.00)
Device type:
r0964[1] = 11200 --> SINAMICS S200 PN
r0964[1] = 11202 --> SINAMICS S200 PTI
r0964[1] = 11210 --> SINAMICS S200 Basic PN
r0964[1] = 11212 --> SINAMICS S200 Basic PTI
r0965 PROFIdrive pro󹪝le number pro󹪝le v
ersion
Data type: Unsigned16 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: Con󹪝guration
Unit: -
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 729