p0977 Save all parameters
Data type: Unsigned16 Visible in: Ext
ended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Can be changed in the operating
stat
e:
Operation
Parameter group: Save & reset
Unit: -
Min:
0
Max:
1
Factory setting:
0
Description: Retentively saves all parameters of the drive system to the non-volatile memory.
When saving, only t
he adjustable parameters intended to be saved are taken into account.
Value: 0: Inactive
1: Save in non-volatile memory - Loaded at POWER ON
Dependency: See also: p0976
NOTICE
The converter power supply may only be switched o
af
t
er saving has been completed (i.e. after saving has started, wait
until the parameter again has a value of 0).
Writing to parameters is inhibited while saving.
r0979[0...30] PROFIdrive encoder format
Data type: Unsigned32 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Parameter group: System identication, Conguration
Unit
: -
Description: Displays the actual position encoder used according to PROFIdrive.
Index: [0] = Header
[1] = Motor encoder type
[2] = Mo
tor encoder resolution
[3] = Shift factor G1_XIST1
[4] = Shift factor G1_XIST2
[5] = Distinguishable revolutions motor encoder
[6...30] = Reserved
Note
Information about the individual indices can be t
aken from the following literature:
PROFIdrive Prole Drive Technology
r0980[0...299] List of existing parameters 1
Data type: Unsigned16 Visible in: Ext
ended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Parameter group: System identication
Unit: -
Description: Displays the parameters that exist for this drive.
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
732 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB