Note
0: No fault present.
r2132 Actual alarm code
Data type: Unsigned16 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: Faults / alarms
Unit: -
Description: Displays the code of the last alarm that occurred.
Note
0: No alarm present.
r2133[0...63] Fault value for 󹪞oat values
Data type:
FloatingPoint32 Visible in: Extended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: Faults / alarms
Unit: -
Description: Displays additional information about the fault that occurred for 󹪞oat v
alues.
Dependency
: See also: r0945, r0947, r0948, r0949, r2109, r2130, r2136
No
te
The bu󹪜er paramet
ers are cyclically updated in the background (refer to status signal in r2139).
r2134[0...63] Alarm value for 󹪞oat values
Data type: FloatingPoint32 Visible in: Ext
ended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: Faults / alarms
Unit: -
Description: Displays additional information about the active alarm for 󹪞oat values.
Dependency: See also: r2122, r2123, r2124, r2125, r2145, r2146, r3123
No
te
The bu󹪜er paramet
ers are cyclically updated in the background (refer to status signal in r2139).
r2136[0...63] Fault time removed in days
Data type: Unsigned16 Visible in: Extended display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: Faults / alarms
Unit: -
Description: Displays the system runtime in days when the fault was removed.
Dependency: See also: r0945, r0947, r0948, r0949, r2109, r2114, r2130, r2133, r3122
NOTICE
The time comprises r2136 (days) and r2109 (milliseconds).
Note
The bu󹪜er paramet
ers are cyclically updated in the background (refer to status signal in r2139).
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
764 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB