Note
This paramet
er is only of signicance for visualization (e.g. using the commissioning tool).
Internally in the drive, the neutral length unit (LU) without dimensions is used for calculations.
p2496 LR dimension system physical length units
S200 Basic PN (EPOS
Lastseite r
otierend),
S200 PN (EPOS
Lastseite rotierend)
Data type: Integer16 Visible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Can be changed in the operating
stat
e:
Commissioning
Parameter group: Position control
Unit: -
Min:
0
Max:
10
Factory setting:
10
Description: Sets the physical length units.
Value: 0: LU (no dimension)
10: °
Note
This par
ameter is only of signicance for visualization (e.g. using the commissioning tool).
Internally in the drive, the neutral length unit (LU) without dimensions is used for calculations.
p2497 LR dimension system physical velocity
Data type: Integer16 V
isible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device congur
ation or driv
e applications
Can be changed in the operating
stat
e:
Commissioning
Parameter group: Position control, Mechanics
Unit: -
Min:
0
Max:
15
Factory setting:
8
Description: Sets the physical unit for the velocities.
Value: 0: 1000LU/min (no dimension)
1: km/h
2: km/min
3: m/h
4: m/min
5: m/s
6: mm/h
7: mm/min
8: mm/s
11: in/min
12: in/s
13: ft/min
14: ft/s
15: mi/h
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 769