c2578 EPOS negative software limit switch
S200 Basic PN (EPOS
Lastseite r
otierend),
S200 PN (EPOS
Lastseite rotierend)
Data type: FloatingPoint32 Visible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: Limit
Unit: °
Description: Signal for the negative software limit switch.
Dependency: See also: c2579, p2580, p2581, c2582
NOTICE
A change to the software limit switch immediately becomes e󹪜ectiv
e.
If the sof
tware limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note
The following applies f
or the setting of the software limit switch:
Negative software limit switch < positive software limit switch
c2579 EPOS positive software limit switch
Data type: FloatingPoint32 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: Limit
Unit: mm
Description: Signal for the positive setpoint limit switch.
Dependency: See also: c2578, p2580, p2581, c2582
NOTICE
A change to the software limit switch immediately becomes e󹪜ective.
If the sof
tware limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note
The following applies f
or the setting of the software limit switch:
Negative software limit switch < positive software limit switch
c2579 EPOS positive software limit switch
S200 Basic PN (EPOS
Lastseite r
otierend),
S200 PN (EPOS
Lastseite rotierend)
Data type: FloatingPoint32 Visible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group: Limit
Unit: °
Description: Signal for the positive setpoint limit switch.
Dependency: See also: c2578, p2580, p2581, c2582
NOTICE
A change to the software limit switch immediately becomes e󹪜ective.
If the sof
tware limit switch is changed, then this results in the positions in the traversing blocks being checked.
Note
The following applies f
or the setting of the software limit switch:
Negative software limit switch < positive software limit switch
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 795