p2599 EPOS home position value
Data type: FloatingPoint32 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Can be changed in the operating
stat
e:
Operation
Parameter group: Homing
Unit: mm
Min:
-2.1474828e+09 [mm]
Max:
2.1474828e+09 [mm]
Factory setting:
0.0000 [mm]
Description: Sets the position value for the home position.
This value is set as t
he actual axis position after homing or adjustment.
Dependency: See also: p2507, c2595, c2596, c2597, c2598
p2599 EPOS home position value
S200 Basic PN (EPOS
Lastseite r
otierend),
S200 PN (EPOS
Lastseite rotierend)
Data type: FloatingPoint32 Visible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Can be changed in the operating
stat
e:
Operation
Parameter group: Homing
Unit: °
Min:
-2.1474828e+09 [°]
Max:
2.1474828e+09 [°]
Factory setting:
0.0000 [°]
Description: Sets the position value for the home position.
This value is set as t
he actual axis position after homing or adjustment.
Dependency: See also: p2507, c2595, c2596, c2597, c2598
p2600 EPOS active homing home position o󹪜set
Data type: FloatingPoint32 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Can be changed in the operating
stat
e:
Operation
Parameter group: Homing
Unit: mm
Min:
-2.1474828e+09 [mm]
Max:
2.1474828e+09 [mm]
Factory setting:
0.0000 [mm]
Description: Sets the home position shift for active homing.
Dependency: See also: c2598
p2600 EPOS active homing home position o󹪜set
S200 Basic PN (EPOS
Lastseite r
otierend),
S200 PN (EPOS
Lastseite rotierend)
Data type: FloatingPoint32 Visible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Can be changed in the operating
stat
e:
Operation
Parameter group: Homing
Unit: °
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 805