p2619[0...n] EPOS traversing block acceleration override
Data type: FloatingPoint32 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Can be changed in the operating
stat
e:
Operation
Parameter group: Traversing blocks
Unit: %
Min:
1.0 [%]
Max:
100.0 [%]
Factory setting:
100.0 [%]
Description: Sets the acceleration override for the traversing block.
The over
ride refers to the maximum acceleration (p2572).
Dependency: The number of indices depends on p2615.
See also: p2572, p2615, p2616, p2617, p2618, p2620, p2621, p2622, p2623
p2620[0...n] EPOS traversing deceleration override
Data type: FloatingPoint32 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Can be changed in the operating
stat
e:
Operation
Parameter group: Traversing blocks
Unit: %
Min:
1.0 [%]
Max:
100.0 [%]
Factory setting:
100.0 [%]
Description: Sets the deceleration override for the traversing block.
The over
ride refers to the maximum deceleration (p2573).
Dependency: The number of indices depends on p2615.
See also: p2573, p2615, p2616, p2617, p2618, p2619, p2621, p2622, p2623
NOTICE
If, when calculating the traversing pr
o󹪝le, it
is identi󹪝ed that the target position of the next block with the programmed
deceleration override will not be reached without direction reversal (󹪞ying block change), then the old (actual)
deceleration override remains e󹪜ective.
p2621[0...n] EPOS traversing block task
Data type: Integer16 Visible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Can be changed in the operating
stat
e:
Operation
Parameter group: Traversing blocks
Unit: -
Min:
1
Max:
9
Factory setting:
1
Description: Sets the required task for the traversing block.
Value: 1: POSITIONING
2: FIXED STOP
3: ENDLESS_POS
4: ENDLESS_NEG
5: WAITING
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 813