r5306[0].0...14 Autotuning status
Data type: Unsigned16 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Parameter group:
Unit: -
Description: Displays the status of the auto tuning functions performed - "Online tuning" and "One Button Tuning".
The functions can be activated via p5300.
Bit arr
ay: Bit Signal name 1 signal 0 signal
00 Proportional gain Kp set Yes No
01 Current setpoint 󹪝lt
er set Y
es No
02 Moment of inertia estimation carried out Yes No
04 Load vibration detection performed Yes No
05 Detected load oscillation set Yes No
06 Current setpoint 󹪝lt
er adapt
ation active Yes No
07 EPOS set Yes No
12 Online tuning active Yes No
13 One Button Tuning successfully completed Yes No
14 Controller parameters reset due to fault Yes No
Dependency: See also: p5300, p5301, p5302
Note
F
or bit 00 = 1: The speed controller g
ain was set using One Button Tuning.
For bit 01 = 1: The current setpoint 󹪝lter was set using One Button Tuning
For bit 02 = 1: The moment of inertia was determined.
For bit 04 = 1: Load oscillation detection was performed using One Button Tuning
For bit 05 = 1: Detected load oscillation suppression was set using One Button Tuning.
For bit 06 = 1: Adaptive resonance 󹪝lters of the online tuning are active.
For bit 12 = 1: Online tuning is active and modi󹪝es the controller.
p5308[0] One Button Tuning distance limiting
Data type: Integer32 V
isible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit device con󹪝gur
ation or driv
e applications
Can be changed in the operating
stat
e:
Ready for operation
Parameter group:
Unit: °
Min:
-30000 [°]
Max:
30000 [°]
Factory setting:
0 [°]
Description: Setting the distance limiting (permissible traversing range of the motor).
The trav
ersing range is limited in the positive and negative directions.
Note
A value of 360 degr
ees corresponds to one motor revolution.
The position before the pulse enable is used as zero point.
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
848 Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB