p10019 SI F-DI self test external dark pulses wait time
S200 PN Data type: FloatingPoint32 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit Safety Integrated application
Can be changed in the operating
s
tat
e:
Commissioning (Safety Integrated)
Parameter group: Safety Integrated
Unit: s
Min:
10 [s]
Max:
3600 [s]
Factory setting:
1020 [s]
Description: Sets the maximum wait time for the dark pulses for the F-DI self test using an externally speci󹪝ed test pulses.
No
te
This paramet
er is only active for F-DIs that are tested using external test pulses (p10041[x] = 3).
c10022 SI STO input terminal
S200 PN Data type: Unsigned8 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit Safety Integrated application
Parameter group: Safety Integrated
Unit: -
Description: Signal for the axis-speci󹪝c selection of function "STO (Saf
e Torque O󹪜)" (control via F-DI).
Note
F-DI: Failsaf
e Digital Input
p10040.0 SI F-DI input mode
S200 PN Data type: Unsigned8 Visible in: S
tandard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit Safety Integrated application
Can be changed in the operating
s
tat
e:
Commissioning (Safety Integrated)
Parameter group: Safety Integrated
Unit: -
Min:
-
Max:
-
Factory setting:
0000 bin
Description: Sets the input mode for the safety digital inputs (F-DI).
Bit array: Bit Signal name 1 signal 0 signal
00 F-DI 0, DI 11+ (X131.5/6) NO contact NC contact
p10041[0...2] SI F-DI self test mode selection
S200 PN Data type: Int
eger16 V
isible in: Standard display
Read permission: Read drive data or acknowledge messages
Write permission: Edit Safety Integrated application
Can be changed in the operating
s
tate:
Commissioning (Safety Integrated)
Parameter group: Safety Integrated
Unit: -
Min:
0
Max:
3
Factory setting:
0
Description: Enable for the F-DI self test.
Appendix
A.3Parameters
SINAMICS S200 PROFINET servo drive system with SIMOTICS S-1FL2
Operating Instructions, 11/2023, FW V6.3, A5E51646752B AB 865