Section 05 ELECTRICAL
Sub-Section 05 (BATTERY)
05-05-4
5. Readjust the electrolyte level to the UPPER
LEVEL line.
1. Battery electrolyte
6. Connect a 2 A battery charger for 10 to 20
hours.
CAUTION : If charging rate raises higher
than 2.4 A reduce it immediately. If cell
temperature rises higher than 50°C (122°F) (if
the casing feels hot) discontinue charging tem-
porarily or reduce the charging rate.
WARNING : Gases given off by a battery
being charged are highly explosive. Al-
ways charge in a well ventilated area. Keep
battery away from cigarettes or open flames.
Always turn battery charger off prior to discon-
necting cables. Otherwise a spark will occur
and battery might explode.
7. Disconnect battery charger.
8. Test battery state of charge. Use a hydrometer.
1. Specific gravity 1.260