3-3
PDW-700/V1 (E)
3-2-2. Error 0X
When errors related to optical drive control or to devices are detected, the following error codes are
displayed.
Main Sub Time data
Maintenance
Drive Description
code code display logger logger
02 020 OOOptical block assembly is recording at maximum laser output.
Perform the pickup lens cleaning. (Refer to Section 4-10-17.)
F2E OOLaser of optical block assembly is determined to be deteriorated in the laser
deterioration assessment for optical block assembly.
F37 OONo movement is detected in the ND filter initial operation check of optical
block assembly.
X25 OOThe laser output of the optical block assembly is abnormal.
X26 OOThe laser output coefficient of the optical block assembly cannot be adjusted.
X27 OOThe laser current of the optical block assembly is abnormal (zero or
excessive).
X28 OOThe optical block assembly laser output is stopped due to the judgment that
no cartridge is inserted.
X37 OOThe ND filter setting of the optical block assembly cannot be changed.
03 060 XOTracking servo of optical block assembly is frequently down.
X54 OONo signal can be detected from the disc required for the focus servo of the
optical block assembly.
X57 OONo control current is detected in the focus servo of the optical block
assembly.
X58 OOExcessive control current is detected in the focus servo of the optical block
assembly.
X67 OONo control current is detected in the tracking servo of the optical block
assembly.
X68 OOExcessive control current is detected in the tracking servo of the optical block
assembly.
04 X7C OOOptical block assembly cannot move to disc’s innermost circumference.
X7D OOOptical block assembly cannot move to disc’s outermost circumference.
06 049 OOSA actuator of optical block assembly cannot move to the target position.
E41 OOThe SA actuator reference position cannot be detected during the startup
adjustment of the optical block assembly.
F41 OOThe SA actuator reference position cannot be detected during the power-on
initialization of the optical block assembly.
08 091 OOSpindle motor does not rotate after the predetermined time has passed (or no
FG signal is detected).
095 OOSpindle motor cannot be stopped (or abnormal FG signal is detected).
292 OOSpindle motor rotation is detected during vertical move of loading.
*
992 OOSpindle motor rotation is detected during vertical move of unloading.
*
* : The vertical move of loading/unloading is also carried out by STBY ON/OFF.