3-5
PDW-700/V1 (E)
3-2-4. Error 3X
When errors related to the optical drive sensor system are detected, the following error codes are dis-
played.
Main Sub Time data
Maintenance
Drive Description
code code display logger logger
34 500 OOLoader position sensor (SE-709 board) is detects abnormal code.
509 OOSensor hole (SE-857,858 board) is detects abnormal code.
35 500 ACC Sensor! XOAbnormality of acceleration sensor is detected.
37 500 High TEMP! XOThe temperature sensor of the optical block assembly is abnormal.
3C 500 HUMID! XODew condensation is detected.
3-2-5. Error 5X
When read data errors are detected, the following error codes are displayed.
Main Sub Time data
Maintenance
Drive Description
code code display logger logger
50 010 (Not displayed) XOBCA area data cannot be read.
011 (Not displayed) XOBCA area data is abnormal.
51 020 DI read err XOPIC area data cannot be read.
021 DI read err XOPIC area data is abnormal.
52 X0B Read err XOAddress cannot be read from disc in optical block assembly.
3-2-6. Error 6X
When errors related to startup operation are detected, the following error codes are displayed.
Main Sub Time data
Maintenance
Drive Description
code code display logger logger
60 E00 (Not displayed) XOOptical block assembly cannot seek to target position during startup.
6F E00 DRV ADJ err XOOptical block assembly startup adjustment cannot be completed.