EasyManua.ls Logo

Sony CBK-HD01 - Error 92

Sony CBK-HD01
300 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
3-7
PDW-700/V1 (E)
3-2-8. Error 92
When synchronization system errors are detected, the following error codes are displayed.
n
System control CPU: IC200 on the SY-355 board
Main Sub Time data
Maintenance
Drive Description
code code display logger logger
92 101 OXSystem control CPU detects REF error.
102 OXSystem control CPU detects frame error in input system.
3-2-9. Error 95
When interface errors between device ICs are detected, the following error codes are displayed.
n
System control CPU: IC200 on the SY-355 board
Optical drive’s system control CPU (DRV): IC600 on the DR-606 board
Main Sub Time data
Maintenance
Drive Description
code code display logger logger
95 101 OXCommunication error between system control CPU and PCI bridge
(IC900/SY-355 board) is detected.
102 OXCommunication error between system control CPU and FAM (IC600/SY-
355 board) is detected.
103 OXCommunication error between system control CPU and composite
decoder (IC100/IV-59 board) is detected.
104 OXCommunication error between system control CPU and MPEG IMX
encoder (IC1600/DVP-45 board) is detected.
107 OXCommunication error between system control CPU and MPEG HD codec
during (TORINO: IC1000,IC1200,IC1400/DVP-45 board) is detected during
recording recording.
109 OXCommunication error between system control CPU and MPEG HD codec
during (TORINO: IC1000,IC1200,IC1400/DVP-45 board) is detected during
playback playback.
108 OXMPEG HD codec (TORINO: IC1000, IC1200, IC1400 / DVP-45 board) has
during become abnormal during recording.
recording
10A OXMPEG HD codec (TORINO: IC1000, IC1200, IC1400 / DVP-45 board) has
during become abnormal during playback.
playback
10C OXSystem control CPU detects an error in LVIS (IC400 / DVP-45 board).
10F OXSystem control CPU detects PROXY VIDEO block in LVIS (IC400 /
during DVP-45 board) error during recording.
recording
110 OXSystem control CPU detects PROXY VIDEO block in LVIS (IC400 /
during DVP-45 board) error during playback.
playback
111 OXCommunication error between system control CPU and PB DSP (IC801/
PB DSP DVP-45 board) is detected.
113 OXCommunication error between system control CPU and REC DSP (IC800/
REC DSP DVP-45 board) is detected.
116 OXCommunication error between system control CPU and PROXY AUDIO
DSP (IC900/DVP-45 board) is detected.
(Continue)

Table of Contents

Related product manuals