Customer Replaceable Units Replacing a Head
Page 192
© Copyright 2021 Stratasys. All rights reserved.
Installing the 3.3/5/12 VDC ATX Power Supply
1. Transfer the mounting bracket to the new power supply.
2. Insert the tabs of the power supply bracket into the slotted holes of the electronics bay
panel. Align the power supply and bracket with the mounting screw location.
3. Use a 3mm hex wrench to reinstall the single mounting screw on the power supply bracket.
4. Connect the power supply cables to the I/O board (J16, J19, J20, J29).
5. Reconnect the cable to the 3.3/5/12 VDC ATX power supply.
6. Make sure that the switch on the power supply is in the ON position.
7. Close the electronics bay doors.
Replacing a Head
When a head reaches the 1500 build hour odometer limit, a warning will be displayed on the
User Interface and the head’s Head Status Icon will be highlighted in red on the Materials page.
You can continue using a head which has exceeded its odometer limit, but it is highly
recommended that you change the head as part quality will be unpredictable. See “Replacing a
Head” (page 121) for instructions on replacing a head.