Table 39: Torque reference parameters
Index Parameter Min Max Unit Default ID Description
P3.3.2.1
Torque Reference
Selection
0 26 0 * 641
The selection of torque
reference. The torque
reference is scaled
between the values of
P3.3.2.2. and P3.3.2.3.
0 = Not used
1 = Keypad
2 = Joystick
3 = AI1
4 = AI2
5 = AI3
6 = AI4
7 = AI5
8 = AI6
9 = ProcessDataIn 1
10 = ProcessDataIn 2
11 = ProcessDataIn 3
12 = ProcessDataIn 4
13 = ProcessDataIn 5
14 = ProcessDataIn 6
15 = ProcessDataIn 7
16 = ProcessDataIn 8
17 = Block Out.1
18 = Block Out.2
19 = Block Out.3
20 = Block Out.4
21 = Block Out.5
22 = Block Out.6
23 = Block Out.7
24 = Block Out.8
25 = Block Out.9
26 = Block Out.10
If you use a fieldbus
protocol where the
torque reference can
be given in Nm units,
you must set
ProcessDataIn1 as the
value to this
parameter.
P3.3.2.2
Torque Minimum
Reference
-300.0 300.0 % 0.0 643
The torque reference
that agrees to the
minimum value of the
reference signal.
PARAMETERS MENU VACON · 127