Table 43: Joystick control parameters
Index Parameter Min Max Unit Default ID Description
P3.3.5.1
Joystick Signal
Selection
0 6 0 451
0 = Not Used
1 = AI1 (0-100%)
2 = AI2 (0-100%)
3 = AI3 (0-100%)
4 = AI4 (0-100%)
5 = AI5 (0-100%)
6 = AI6 (0-100%)
P3.3.5.2
Joystick Dead Zone 0.0 20.0 % 2.0 384
When the reference is
between 0 and 0 ± this
parameter, the
reference is set to 0.
P3.3.5.3
Joystick Sleep Zone 0.0 20.0 % 0.0 385
The AC drive stops if
the joystick reference
stays in the sleep zone
for longer than the
sleep delay.
0 = Not used
The Sleep function is
available only if you
use joystick to control
the frequency
reference.
P3.3.5.4
Joystick Sleep Delay 0.00 300.00 s 0.00 386
The AC drive stops if
the joystick reference
stays in the sleep zone
for longer than the
sleep delay.
The Sleep function is
available only if you
use joystick to control
the frequency
reference.
VACON · 132 PARAMETERS MENU
5
TEL. +358 (0)201 2121 · FAX +358 (0)201 212 205

Table of Contents

Other manuals for Vacon 100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Vacon 100 and is the answer not in the manual?

Vacon 100 Specifications

General IconGeneral
Product typeAC Drive
Enclosure classIP20
EMC filterBuilt-in
Power0.25 kW - 5.5 kW
Cooling methodFan
Braking chopperOptional

Related product manuals