Table 83: Setpoint settings
Index Parameter Min Max Unit Default ID Description
P3.13.2.7 Setpoint 1 minimum -200.00 200.00 % 0.00 1069
The minimum value at
the analogue signal
minimum.
P3.13.2.8 Setpoint 1 maximum -200.00 200.00 % 100.00 1070
The maximum value at
the analogue signal
maximum.
P3.13.2.9 Setpoint 1 boost -2.0 2.0 x 1.0 1071
It is possible to boost the
setpoint with a digital
input.
P3.13.2.10
Setpoint source 2
selection
0 22 2 431
See P3.13.2.6.
P3.13.2.11 Setpoint 2 minimum -200.00 200.00 % 0.00 1073
The minimum value at
the analogue signal
minimum.
P3.13.2.12 Setpoint 2 maximum -200.00 200.00 % 100.00 1074
The maximum value at
the analogue signal
maximum.
P3.13.2.13 Setpoint 2 boost -2.0 2.0 x 1.0 1078 See P3.13.2.10.
* = The selection of the application with parameter P1.2 Application gives the default value.
See the default values in Chapter 11 Appendix 1.
VACON · 176 PARAMETERS MENU