Display Description Remedy
The button is blocked. Can the button be freed again by
hand?
Contact a qualified service
technician.
V1207223
Timer mode not
allowed
7
Timer mode is not permitted
during ADR mode.
(a)
Contact a qualified service
technician.
V1207224
Operation
not supported
8
The heater is in auxiliary
heating mode via Switching
Plus and cannot be operated
via Timer control unit during
this time.
Contact a qualified service
technician.
V1207225
CAN communication
error
9
Communication error on the
CAN bus link.
Contact a qualified service
technician.
a) ADR mode is reserved for vehicles transporting hazardous goods on the road. Not applicable for
the machine.
NOTE!
If you are unable to remedy the error or fault,
contact a qualified service technician.
Winter season preparation for auxiliary
heater
Operator should exhaust remaining summer diesel
in fuel line of auxiliary heater before winter season
comes. Remaining summer diesel can cause
plugging in fuel line if temperature drops in sudden
because of wax crystallization. Run auxiliary heater
at least 15 minutes until remaining diesel is
exhausted.
When operator runs machine in winter season, it is
recommended to fill fuel tank over 70%. If fuel tank
has much empty space, it makes moisture inside of
fuel tank. It can go to fuel line of auxiliary heater and
frozen moisture sometimes makes fuel feeding
problem.
162
Other controls
Operator comfort