Fuel system, bleeding
Air must be bled out of the fuel injection system
whenever the machine runs out of fuel while the
engine is running.
NOTICE
Under no circumstances must starting attempts be
made before the system has been bled. The fuel
feed pump may be seriously damaged.
NOTE!
Do not spill fuel on electrical components.
1 Turn hand pump (A) counterclockwise to unlock
the plunger.
2 Pump hand pump (A) until a heavy resistance
can be felt in the hand pump.
3 Push hand pump (A) fully and turn it clockwise
to lock the plunger.
4 Start the engine and let it run in idle for 3 minutes.
5 If the engine is difficult to start, repeat (1) to (3).
NOTE!
Do not use the hand pump when the engine is
running.
6 Check for leakages.
A Hand pump
328
Maintenance
Maintenance service, when required