Loading...
Park
machine
Service
needed
Derate
active
Warning, red
- buzzer sounds
- red central
warning on
- engine
performance is
significantly
reduced
1 Park the machine in a
non-heat-sensitive
area.
2 Move the control
lockout lever down to
lock the system.
3 Turn off the engine.
4 Contact a qualified
service technician for
replacement of the
diesel particulate
filter.
NOTE!
The soot load can
only be reset by
qualified service
technician.
Regeneratio
n not needed
Information, blue
V1088268
- buzzer sounds
- blue central
warning on
1 No action required.
Continue
operation
Low
temperature
Regeneratio
n pending
Warning, amber
- buzzer sounds
- amber central
warning on
1 Continue operating
the machine to warm
up the exhaust
aftertreatment
system.
Service
needed
Regeneratio
n not
possible
System
failure
Warning, amber
V1203417
- buzzer sounds
- amber central
warning on
1 Service required.
2 Contact a qualified
service technician.
Lower CTRL
lockout lever
Regeneratio
n needed
Warning, amber
- buzzer sounds
- amber central
warning on
1 Park the machine in a
non-heat-sensitive
area.
2 Move the control
lockout lever down to
lock the system.
3 Start regeneration.
Operating instructions
Exhaust aftertreatment system
189

Table of Contents