Appendix A SCPI Command Reference
MEASure subsystem
WCDMA Options Version 6.20
327
:MEASure[:CONTinuous]:PSUPply:ACURrent
:MEASure[:CONTinuous]:PSUPply:PCURrent
Description
Starts a continuous measurement of the power consumption test. To read out the
latest measurement result, use the :FETCh:PSUP:APOW? query.
Note: Any power and current consumption measurement will need the MS Power
Supply and the Current Measurement Options to be installed on your Willtek 4400.
Query
The query form of this command starts the measurements and - after all measure-
ments have been completed and all measurement results obtained - delivers back a
string containing the measurement result value. The value represents the average
power consumption in mW.
Example
:MEAS:PSUP:APOW?
In this case, all the average power consumption measurements is performed. As soon
as the measurement has been completed, a string will be delivered back containing
the measurement result value, for example "863.6"
.
Syntax
:MEASure[:CONTinuous]:PSUPply:ACURrent
Parameters
There are no parameters.
Description
Starts a continuous measurement of the average current consumption test. To read
out the latest measurement result, use the :FETCh:PSUP:ACUR command.
Any power and current consumption measurement will need the MS Power Supply
and the Current Measurement Options to be installed on your Willtek 4400.
Query
The query form of this command starts the measurement and - after the measure-
ment has been completed and the measurement result obtained - delivers back a
string containing a floating point real number representing the average current con-
sumption in mA.
Example
:MEAS:PSUP:ACUR?
In this case, the average current consumption measurement is performed. As soon as
the measurement has been completed, a string will be delivered back containing the
measurement result value, for example "304.2,"
.
Syntax
:MEASure[:CONTinuous]:PSUPply:PCURrent
Parameters
There are no parameters.
Description
Starts a continuous measurement of the peak current consumption test. To read out
the latest measurement result, use the :FETCh:PSUP:PCUR command.
Any power and current consumption measurement will need the MS Power Supply
and the Current Measurement Options to be installed on your Willtek 4400.
Query
The query form of this command starts the measurement and - after the measure-
ment has been completed and the measurement result obtained - delivers back a
string containing a floating point real number representing the peak current con-
sumption in mA.
Example
:MEAS:PSUP:PCUR?
In this case, all the peak current consumption measurement is performed. As soon as
the measurement has been completed, a string will be delivered back containing the
measurement result value, for example
"1352.9"
.