Appendix A SCPI Command Reference
CALL subsystem
WCDMA Options Version 6.20
317
CALL subsystem
This subsystem contains commands
– for call setup and handling procedures and
– to read out the measurement report, generated by the mobile.
:CALL:WCDMa:POWer:ULTArget
:CALL:WCDMa:POWer:ULTArget:FORCe
:CALL:WCDMa:POWer:PREAmble
Description
With the help of this command, you may create a coupling loss description table,
similar to how you would do it on the graphical user interface of the Willtek 4400.
For further details, please refer to section Coupling Loss.
Query
There is no query form of this command available.
Example
:CONF:WCDMA:COUP:DATA "Motorola 7389 with cable
#23",825.0,15.0,1750.0,19.0
Syntax
:CALL:WCDMa:POWer:ULTArget
<Real1>
Parameters
Real1 is a floating point real number. The minimum value is -50, the maximum
value
33. The minimum resolution is 0.1. The default value is -50.
Description
This command will set the UL target power.
Query
This query gets the UL target power.
Example
:CALL:WCDM:POW:ULTA -10.0:CALL:WCDM:POW:ULTA?
Value returned in this example: -10.0
Syntax
:CALL:WCDMa:POWer:ULTArget:FORCe <PredefExp>
Parameters
PredefExp
is one of the following predefined expressions: NONe|MINi-
mum|MAXimum
. Default is NONe.
Description
This command forces the UE to transmit with minimum or maximum power. If set to
NONe the UE is set to transmit with the value specified by command:
CALL:WCDM:POW:ULTA.
Query
The query form of this command returns the current setting for
PredefExp.
Example
:CALL:WCDM:POW:ULTA:FORC MAX
:CALL:WCDM:POW:ULTA:FORC?
Value returned in this example: MAX
.
Syntax
:CALL:WCDMa:POWer:PREAmble?
Parameters
There are no parameters.
Description
There is no set form of this command.