Appendix A SCPI Command Reference
CALCulate Subsystem
WCDMA Options Version 6.20
403
:CALCulate:WCDMa:RFTX:MMINimum?
:CALCulate:WCDMa:RFTX:MMAXimum?
Parameters
There are no parameters.
Description
There is solely a query form of this command available.
Query
There is a query form which returns the stored settings.
Example
:MEAS:WCDM:RFTX:FREQ
:CALC:RES
...(other SCPI commands)...
:CALC:WCDM:RFTX:MAV?
In this example, first a continuous measurement of the mobile's frequency error is
started. After some time, the :CALC:WCDM:RFTX:MAV
command is used to read
out the average frequency deviation of the mobile. The string returned in this exam-
ple is
"12.9".
Syntax
:CALCulate:WCDMa:RFTX:MMINimum?
Parameters
There are no parameters.
Description
There is solely a query form of this command available.
Query
Returns the minimum measurement result value of the TX measurement started last.
The string delivered will contain as many minimum values as measurement types per-
formed. The single minimum values will always have the format of floating point real
numbers and will be separated by commas.
Example
:MEAS:WCDM:RFTX:FREQ
:CALC:RES
...(other SCPI commands)...
:CALC:WCDM:RFTX:MMIN?
In this example, first a continuous measurement of the mobile's frequency error is
started. After some time, the :CALC:WCDM:RFTX:MMAX
command is used to read
out the minimum frequency deviation of the mobile. The string returned in this exam-
ple is
"10.2".
Syntax
:CALCulate:WCDMa:RFTX:MMAXimum?
Parameters
There are no parameters.
Description
There is solely a query form of this command available.
Query
Returns the maximum measurement result value of the TX measurement started last.
The string delivered will contain as many maximum values as measurement types
performed. The single maximum values will always have the format of floating point
real numbers and will be separated by commas.