Maintenance
55623/A1
Winterthur Gas & Diesel Ltd.
5/ 5
6. Completion
1) Install the leakage pipes (4), (5) to the
flow limiting valve (1, Fig. 7).
2) Install the HP fuel pipes, refer to
8733.1.
3) Cut in the injection, refer to the
Operation Manual, 05101.
4) Operate the engine for a minimum of
one hour with marine diesel oil. For
more data, refer to the Operation
Manual 05101.
7. Storage
Before you put an flow limiting valve (FLV) into storage, do the procedure that follows:
1) Use a vacuum cleaner to remove dirt from all openings.
2) Clean the FLV.
3) Lubricate the FLV correctly.
4) Put the FLV in a plastic bag.
5) Remove as much air as possible from the plastic bag.
6) Seal the plastic bag.
2015
Injection Control Unit: Removal and Installation
1
WCH03227
3
5
4
2
Fig. 7

Table of Contents