Phaser 3600 Printer Service Manual 7-21
Service Parts Disassembly
Tray 1 (MPT) Feed Sensor (PL1.3.97)
Caution
When removing the plastic cover in the step 5, lift the edge nearest the sensor
first then the other end, being careful not to bend the actuator.
1. Remove the Tray 1 (MPT) Assembly (page 7-14).
2. Remove the 6 screws from the HVPS board to expose the connectors.
3. Disconnect CN3 from the HVPS board.
4. Unlace the 3-wire harness of CN3 from the HVPS.
5. Remove the plastic cover covering the sensor.
6. Gently push the plastic hook away from the sensor board to remove the
board and sensor.
s3600-111
Hook