<1> Parameter setting value is not reset to the default value when the drive is initialized.
<2>
Setting range is 0 to 7 in models 4A0930 and 4A1200.
<3> Default setting value is determined by he Application Preset selected in parameter A1-06.
u
A2: User Parameters
No.
(Addr.
Hex)
Name LCD Display Description Values Page
A2-01 to
A2-32
(0106 to
0125)
User Parameters 1 to 32 User Param 1 - 32
Recently edited parameters are listed here. The user can also
select parameters to appear here for quicker access.
Default:
<1>
Range: b1-01 to
o4-13
A2-33
(0126)
User Parameter
Automatic Selection
User Parms Sel
0: Disabled
1: Enabled
0: Parameters A2-01 to A2-32 are reserved for the user to create
a list of User Parameters.
1:
Save history of recently viewed parameters. Recently edited
parameters will be saved to A2-17 through A2-32 for quicker
access.
Default: 1
<2>
Range: 0, 1
<1> Default setting value is determined by the Application Preset selected in parameter A1-06.
<2>
Default setting value is determined by parameter A1-06. Default is 0 when A1-06 = 0, and 1 when A1-06 ≠ 0.
B.1 A: Initialization Parameters
YASKAWA ELECTRIC TOEP C710616 41G YASKAWA AC Drive - A1000 Quick Start Guide
251
B
Parameter List

Table of Contents