u
d7: Offset Frequency
No.
(Addr.
Hex)
Name LCD Display Description Setting Page
d7-01
(02B2)
Offset Frequency 1 Offset Freq 1
Added to the frequency reference when the digital input
“Frequency offset 1” (H1-oo = 44) is switched on. A setting
of 100% is equal to the drive maximum output current.
Default: 0.0%
Min.: -100.0
Max.: 100.0
d7-02
(02B3)
Offset Frequency 2 Offset Freq 2
Added to the frequency reference when the digital input
“Frequency offset 2” (H1-oo = 45) is switched on. A setting
of 100% is equal to the drive maximum output current.
Default: 0.0%
Min.: -100.0
Max.: 100.0
d7-03
(02B4)
Offset Frequency 3 Offset Freq 3
Added to the frequency reference when the digital input
“Frequency offset 3” (H1-oo = 46) is switched on. A setting
of 100% is equal to the drive maximum output current.
Default: 0.0%
Min.: -100.0
Max.: 100.0
B.4 d: References