3.6 Application Preset
184 YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual
No. Name
Application Preset (A1-06 Setting)
Crane (Hoist)
(1)
Crane (Traveling)
(2)
Closed Loop Crane (Hoist)
(3)
S1-03
Brake Delay Frequency
3.0 Hz 0.0 Hz 0.0 Hz
S1-04
Brake Delay Time
0.30 s 0.00 s 0.00 s
S1-09
Torque Compensation (FWD)
50% - 0%
S1-12
Brake Hold Frequency (FWD)
3.0 Hz 0.0 Hz 3.0 Hz
S1-13
Brake Hold Frequency (REV)
3.0 Hz 0.0 Hz 3.0 Hz
S1-14
Slip Prevention Frequency
3.0 Hz 0.0 Hz 0.0 Hz
S1-15
Slip Prevention Time
0.30 s 0.00 s 0.00 s
S1-16
Sequence Fault SE1 Detect Time
0.30 s 0.00 s 0.30 s
S1-17
Sequence Fault SE2 Detect Time
1.00 s 0.00 s 1.00 s
S1-18
Sequence Fault SE3 Detect Time
0.50 s 0.00 s 0.50 s
S1-19
Sequence Fault SE4 Detect Time
0.50 s 0.00 s 0.50 s
S1-54
Brake Sequence Selection
1: Enabled 0: Disabled 1: Enabled
Note:
When A1-06 [Application Preset] 0, the drive shows different parameters on the keypad for different application presets. Set A1-13
[All Function Parameter Display] = 0 to show all available parameters.