Parameter Details
11
11.11 o: Keypad-Related Settings
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 791
o3: Copy Function
o3 parameters set the operation of the parameter backup function.
o3-01: Copy Keypad Function Selection
No.
(Hex.)
Name Description
Default
(Range)
o3-01
(0515)
Copy Keypad Function
Selection
Sets the function to use the keypad to save and copy drive parameters to a different drive.
0
(0 - 3)
0 : Copy Select
1 : Backup (drive keypad)
The parameter setting values are read from the drive and stored in the keypad.
2 : Restore (keypad drive)
Copies the parameter setting values stored in the keypad to another drive.
3 : Verify (check for mismatch)
Verifies that parameter setting values in the drive match the parameters stored in the keypad.
o3-02: Copy Allowed Selection
No.
(Hex.)
Name Description
Default
(Range)
o3-02
(0516)
Copy Allowed Selection
Sets the copy function when o3-01 = 1 [Copy Keypad Function Selection = Backup (drive
keypad)].
0
(0, 1)
Note:
When you select [Parameter Backup] on the keypad menu screen to do the backup function, the drive automatically sets o3-02 = 1.
0 : Disabled
1 : Enabled
o3-04: Select Backup/Restore Location
No.
(Hex.)
Name Description
Default
(Range)
o3-04
(0B3E)
Select Backup/Restore
Location
Sets the storage location for drive parameters when you back up and restore parameters. This
parameter is only available when using an LCD keypad.
0
(0 - 3)
You can use the LCD keypad to make a maximum of 4 parameter backup sets.
0 : Memory Location 1
1 : Memory Location 2
2 : Memory Location 3
3 : Memory Location 4
o3-05: Select Items to Backup/Restore
No.
(Hex.)
Name Description
Default
(Range)
o3-05
(0BDA)
Select Items to Backup/
Restore
Sets which parameters are backed up, restored, and referenced. This parameter is only available
on an LCD keypad.
0
(0, 1)
0 : Standard Parameters
1 : Standard + DWEZ Parameters
o3-06: Auto Parameter Backup Selection
No.
(Hex.)
Name Description
Default
(Range)
o3-06
(0BDE)
Auto Parameter Backup
Selection
Sets the function that automatically backs up parameters. This parameter is only available when
using an LCD keypad.
1
(0, 1)
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV
V/f
CL-V/f
OLV
CLV
AOLV