Parameter Details
11
11.4 C: Tuning
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 605
Figure 11.32 S-Curve Timing Diagram - Forward/Reverse Operation
Note:
Setting the S-curve will increase the acceleration and deceleration times.
■ C2-01: S-Curve Time @ Start of Accel
No.
(Hex.)
Name Description
Default
(Range)
C2-01
(020B)
S-Curve Time @ Start of
Accel
Sets the S-curve acceleration time at start.
Determined by A1-02
(0.00 - 10.00 s)
■ C2-02: S-Curve Time @ End of Accel
No.
(Hex.)
Name Description
Default
(Range)
C2-02
(020C)
S-Curve Time @ End of
Accel
Sets the S-curve acceleration time at completion.
0.20 s
(0.00 - 10.00 s)
■ C2-03: S-Curve Time @ Start of Decel
No.
(Hex.)
Name Description
Default
(Range)
C2-03
(020D)
S-Curve Time @ Start of
Decel
Sets the S-curve deceleration time at start.
0.20 s
(0.00 - 10.00 s)
■ C2-04: S-Curve Time @ End of Decel
No.
(Hex.)
Name Description
Default
(Range)
C2-04
(020E)
S-Curve Time @ End of
Decel
Sets the S-curve deceleration time at completion.
0.00 s
(0.00 - 10.00 s)
◆ C3: Slip Compensation
The Slip Compensation function improves the speed accuracy of an induction motor. As loads on induction
motors increase, motor slip increases and motor speed decreases. By adjusting the output frequency in accordance
with the motor load, it compensates the slip and makes the motor speed equal to the frequency reference.
■ C3-01: Slip Compensation Gain
No.
(Hex.)
Name Description
Default
(Range)
C3-01
(020F)
RUN
Slip Compensation Gain
Sets the gain for the slip compensation function. Usually it is not necessary to change this setting.
Determined by A1-02
(0.0 - 2.5)