Parameter List
10
10.20 Parameters Changed by o2-04 [Drive Model (KVA) Selection]
YASKAWA SIEPC71061723A YASKAWA AC Drive CR700 Technical Manual 561
No. Name Unit Default
- Drive Model - 2215 2283 2346 2415
o2-04
Drive Model (KVA)
Selection
Hex. 75 76 77 78
Motor 1: E2-11
Motor 2: E4-11
Motor 3: E7-31
Motor Rated Power kW 55 75 90 110
Motor 1: E2-06
Motor 2: E4-06
Motor Leakage
Inductance
% 20.5 20 20 20
Motor 1: E2-10
Motor 2: E4-10
Motor Iron Loss W 960 1200 1200 1200
L2-03
Minimum Baseblock
Time
s 1.3 1.5 1.5 1.7
L2-05
Undervoltage Detection
Lvl (Uv1)
- 190 190 190 190
L3-24
Motor Accel Time @
Rated Torque
s 0.317 0.533 0.592 0.646
L8-02 Overheat Alarm Level °C 105 105 120 120
L8-09
Output Ground Fault
Detection
- 1 1 1 1
L8-38
Carrier Frequency
Reduction
- 2 2 2 2
L8-39
Carrier Freq Reduction
during oL
- 2 2 2 2
n1-01
Hunting Prevention
Selection
- 2 2 2 2
n1-03
Hunting Prevention
Time Constant
ms 10 10 100 100
n1-16
Hunting Prevention
High Fc Gain
- 0.50 0.50 1.00 1.00
n2-01
Automatic Freq
Regulator Gain(F)
- 1.00 1.00 1.00 1.00
n5-02
Motor Inertia
Acceleration Time
s 0.317 0.533 0.592 0.646
◆ 400 V Class
No. Name Unit Default
- Drive Model - 4002 4003 4005 4006
o2-04
Drive Model (KVA)
Selection
Hex. 92 93 94 95
Motor 1: E2-11
Motor 2: E4-11
Motor 3: E7-31
Motor Rated Power kW 0.4 1.1 1.5 2.2
Motor 1: C5-17
Motor 2: C5-37
Motor Inertia kgm
2
0.0015 0.0028 0.0068 0.0088
C6-02
Carrier Frequency
Selection
- 1 1 1 1
E1-01
Input AC Supply
Voltage
V 400 400 400 400
Motor 1: E2-01
Motor 2: E4-01
Motor 3: E7-21
Motor Rated Current
(FLA)
A 1 1.6 3.1 4.2
Motor 1: E2-02
Motor 2: E4-02
Motor Rated Slip Hz 2.9 2.6 2.5 3
Motor 1: E2-03
Motor 2: E4-03
Motor No-Load
Current
A 0.6 0.8 1.4 1.5
Motor 1: E2-05
Motor 2: E4-05
Motor 3: E7-25
Motor Line-to-Line
Resistance
Ω 38.198 22.459 10.1 6.495
Motor 1: E2-06
Motor 2: E4-06
Motor Leakage
Inductance
% 18.2 14.3 18.3 18.7